A fire risk assessment is a living document, not a one-off purchase. The law requires it to stay suitable and sufficient, which means reviewing it at planned intervals and immediately when something material changes.
What the law actually requires
The Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to keep the assessment up to date. It does not set a single fixed review date for every building, which is why the assessment itself should state when the next review is due.
Annual review is widely accepted as good practice for commercial premises, with more frequent reviews where risk is higher. The important point is that the review is recorded, not just carried out.
Events that require an immediate review
A review cannot wait for the next scheduled date if the premises or the way they are used has changed. In practice these are the triggers we see most often.
- A change of use, occupancy or the number of people on site
- Refurbishment, layout changes or new partitions and escape routes
- New processes, equipment or flammable storage
- A fire, near miss or false alarm trend
- Changes to fire safety legislation or guidance
- A significant change in the responsible person or management arrangements
- Findings from a fire service visit or insurer survey
Recommended review frequency by premises type
These are the intervals we normally recommend. They are starting points: the assessment itself should set the review date based on what it found.
- Low-risk offices and small retail units — annually
- Warehouses, light industrial and mixed-use buildings — annually, or sooner after layout changes
- Hotels, care homes, licensed premises and anywhere people sleep — annually, with interim checks
- Blocks of flats — annually for communal areas, plus inspection of fire doors and escape routes
- Vacant premises — at each change of status, and at least annually
Additional duties for buildings over 11 metres
The Fire Safety (England) Regulations 2022 added duties for residential buildings. Responsible persons for buildings at least 11 metres high must record their fire safety arrangements and information about the building, and for buildings at least 18 metres high they must share specified information with the local fire and rescue service.
These duties sit alongside the fire risk assessment rather than replacing it, and they are usually checked together during an assessment.
How to keep the assessment current
Keep the assessment with a simple fire log that records alarm tests, extinguisher checks, fire door inspections, staff training and drills. When the annual review comes round, that log is the evidence that the arrangements described in the assessment are actually operating.
Our annual compliance packages include a scheduled review so the document does not quietly go out of date.